PVG Power Venters are ETL-Listed
The PVG Power Venter side-wall vents a single 24 VAC-controlled furnace, boiler, or water heater which burns natural or LP gas. The PVG can also vent a single 24 VAC-controlled gas-fired furnace or boiler, and a 30 millivolt residential gas-fired water heater.
The indoor mounted PVG Power Venters provide a safe, efficient, and economical power venting system for gas heating appliances. All controls are built into these units. A Vent Hood is required to terminate the vent system.
To size a PVG Power Venter, you will need to know the total input firing rate and total equivalent length of vent pipe. Refer to Power Venter System installation manual or Contractors Reference Guide for sizing details.
- Dimensions: 7" L (front to back) x 9-1/4" W x 7-1/2" H
- 115V/60Hz/2.1A
- 3000 RPM
- Thermal protection
- Thermostat or aquastat calls for heat and starts the power venter
- The pressure switch senses sufficient air flow and allows burners to start
- The power venter draws combustion air through the system and forces gases outside through an external vent hood
- Draft hood or barometric draft control between the appliances and the power venter maintains consistent air flow
- After the thermostat is satisfied, the burner shuts down and the post purge control clears the venting system of combustion gases
- The power venter shuts down